Water heaters require two seismic straps.
Tankless water heater code requirements california.
If the window does not open the tankless water heater clearance from a window requires a 12 inch setback.
The appliance is draft hood equipped.
General tankless water heater requirements.
Cepe certified experienced low rates same day turnaround.
The bottom strap must be located at least 4 away from the water heater controls.
Tankless water heaters and title 24 california title 24 energy calculations and reports for all building projects.
The input rating is less than the maximum capacity given in table 510 1 2 3.
Installing a tank water heater might seem easy but homeowners who refinish their basements often create a number of code violations with respect to the water heater.
Tankless water heaters should not be installed near dryer vents or intake air vents.
All original and replacement water heater installations are required to be in compliance with california plumbing code cpc.
If the unit is vented to the outside then it needs 12 inches of clearance from a door or window.
Call toll free 888 828 9488 for more information.
Based on the 2010 california plumbing code.
The vent connector length is limited to 18 inches per inch 18 mm mm of vent connector diameter.
As well hot water heaters cannot be located in bedrooms or bathrooms.
This is not an all inclusive list and additional items may be required as determined during the inspection.
The california water heater code is part of a larger statewide california plumbing code and has several very specific restrictions.
A plumbing permit is required for the installation of a water heater.
Code expert glenn mathewson describes 10 common water heater code issues including confusion about drip pans and drains unsupported expansion tanks and plastic vents lack of combustion air and more.
For a water heater the outdoor design temperature shall be not less than 5 f 15 c.
Or replacing a water heater.
As tiny amounts of carbon monoxide co may be released from gas water heater vents this regulation prevents human contact and accidents.
Water heaters with an input rating greater than 6 800 btu per hour 2kw require isolation valves on both cold water supply and hot water pipe leaving the water heater and hose bibs or other fittings on each valve for flushing the water heater when the valves are closed.
The purpose of this technical bulletin is to provide guidelines for water heater installations.
Approved location to prevent accidents water heaters cannot be located in a closet unless it is reserved for only the water heater.